Recalls › 03V100000

NHTSA recall 03V100000

Fuel system, gasoline › Delivery › Hoses, lines/piping, and fittings

Home And Park Roadtrek 190

Reported Mar 17, 2003125 vehicles affectedHOME & PARK MOTORHOMESMaker’s number 2003-01

The defect

On certain motor homes built on chevrolet g-van chassis, the chassis fuel return line, which IS tapped to supply fuel to the generator, has been found to have pressures that exceed the maximum allowed by the generator manufacturer. as a result, if the generator IS operated at the same time the chassis engine IS running, excess fuel could be delivered to the generator, creating a potential for a generator stall and possible fuel spill.

The risk

In the event of a fuel spill, a fire could occur.

The remedy

Dealers will install an approved kit that draws the generator fuel supply directly from the fuel tank. owner notification IS expected to begin during march or april 2003. owners who take their vehicles to an authorized dealer on an agreed upon service date and do not receive the free remedy within a reasonable time should contact home & park at 1-888-762-3873.

Official recall at NHTSA ↗

Ask AI about this recallChatGPTClaudePerplexityGoogle AIGrok

Vehicles in this recall

Notes

Home & park recall no. 2003-01.Customers can also contact the national highway traffic safety administration's auto safety hotline at 1-888-dash-2-dot (1-888-327-4236).