Recalls › 04V453000

NHTSA recall 04V453000

Fuel system, other › Storage › Tank assembly › Pressure relief devices

Sterling Condor

Reported Sep 15, 200467 vehicles affectedFREIGHTLINER LLCMaker’s number FL-432Built Oct 30, 2003 – Jun 25, 2004

The defect

On certain trucks equipped with liquid natural gas (lng) style tanks, neither the primary nor the secondary relief valves have opened to relieve tank pressure under certain conditions. specifically, the introduction of water into the discharge side of both of these valves simultaneously and subsequent freezing in service can render the valves temporarily inoperative.

The risk

This condition creates the risk of tank over-pressurization and a potential tank rupture, possibly resulting in serious injury or death.

The remedy

Dealers will retrofit the lng tanks on the vehicles with a new primary relief valve pipe away tube and a new ventilated shroud cover; ensure the relief valves are moisture free and ensure that the red cover IS presently in place on the secondary relief valve. the recall began october 14, 2004. Owners may contact freightliner at 1-800-547-0712.

Official recall at NHTSA ↗

Ask AI about this recallChatGPTClaudePerplexityGoogle AIGrok

Vehicles in this recall

Notes

Freightliner recall no. Fl-432.customers can also contact the national highway traffic safety administration's auto safety hotline at 1-888-dash-2-dot (1-888-327-4236).