NHTSA recall 94V130000
Electrical system › Wiring
Oshkosh Mbfd and 4 more
The defect
Depending on the location and the electrical demand, a combination of corrosion and heat can cause a momentary break on either of two electrical circuits at the bulkhead connector (21 or 29). If these circuits fail, the ignition, parking light, fuel pump, fuse panels and the secondary electrical braking system will lose power.
The risk
Loss of power to the secondary electrical braking system can result in increased stopping distances and possible vehicle accident.
The remedy
Power from the battery will be run directly to the stop lamp switch and the ignition switch. This will eliminate the bulkhead connection for the ignition circuit and back-up brake circuit as well as dividing up the load on the two questionable circuits.