These records cover every 2018 Ubco 2X2. To see whether one car still needs a recall repair, decode its VIN or check it with NHTSA.
Service bulletins
Technical service bulletins and other communications the manufacturer sent dealers about this vehicle. Ask a dealer for the full document by its number.
10172891A number of failures of the speedometer housing & wiring connection have been reported on bikes with VIN numbers between J600001 to J600581. The failure mode has been identified as being excessive vibration from the handle bars passing through to the mounting bolts of the speedometer. This can cause the display not to function correctly. It also has been noted that in certain cases that when the bike is turned off or power removed from the clock, the time on the clock resets back to zero. This is the result of a missing capacitor on the PCB. A speedometer is supplied to resolve this.
10162812It has been observed that axle wheels nuts on the 2018 UBCO 2x2 can loosen over time in high vibration environments. Therefore, the following servicing update is being issued and is recommended to be carried out on all UBCO 2018 2x2s ? Apply Loctite 243 to axle thread prior to torqueing axle nuts to 80Nm
10162811The default speed limit of the 2018 UBCO 2x2 will be reducing to 45kmph/28mph. This is due to the entry of the UBCO 2x2 into the European Union - where a maximum speed limit of 45kmph/28mph applies. The new default speed limit will be implemented via firmware version x1.00.330, updated via the UBCO User App. For territories with the higher speed limit of 50kmph/30mph, it is essential that location services are enabled for the UBCO User App prior to installing firmware version x1.00.330. This will allow a speed limit of 50kmph/30mph to be applied to the 2018 UBCO 2x2 within the noted territory.
10159782This Service Bulletin provides answers to FAQ?s UBCO has received on battery charging and charge time. It serves as reference information only
10159781This notification serves as a reminder that spoke tension on the all models of the UBCO 2x2 must be checked at PDI, 10hr service and then subsequent services.
10159780The following Bulletin provides an update on the issue identified in the Service Bulletin UBC0005 (Formally UBC-L4X2M-09) regarding motor controllers
10150054This service Bulletin provides details on the possibility for motor controllers to fail on start-up or shortly afterwards during operation. If the failure happens during start-up, the vehicle will not operate. If the failure happens during operation, the vehicle will lose power and decelerate. This communication instructs dealers to perform appropriate testing.