Recalls › 04V068000

NHTSA recall 04V068000

Fuel system, gasoline › Storage › Tank assembly › Filler pipe and cap

Porsche Cayenne S and 1 more

Reported Feb 18, 200435 vehicles affectedPORSCHE CARS NORTH AMERICA, INC.

The defect

On certain sport utility vehicles, if the ground connection between the spiral ring of the tank filler neck and the connecting pipe to the fuel tank IS inadequate, the flow of fuel during refueling can create an electrostatic charge, which could discharge and spark. this spark could ignite fuel vapors in the area outside the tank filler neck that could lead to a muffled detonation.

The risk

Due to such a startling event, the individual refueling the vehicle could remove the fuel nozzle at precisely the moment of the detonation without first stopping the fueling process. in such a circumstance, fuel escaping outside of the fuel tank may ignite, resulting in a fire.

The remedy

Dealers will inspect the ground connection and, if necessary, corrected. owner notification began on march 29, 2004. owners should contact porsche at 1-800-545-8039.

Official recall at NHTSA ↗

Ask AI about this recallChatGPTClaudePerplexityGoogle AIGrok

Vehicles in this recall

Notes

Customers can also contact the national highway traffic safety administration's auto safety hotline at 1-888-dash-2-dot (1-888-327-4236).