Altec Industries Inc. (Altec) is recalling certain 2016-2022 van mounted AT200A and AT30G vehicles. The ground-fault circuit interrupter (GFCI) outlet may not provide adequate circuit protection against an electrical overload condition.
Risk and remedy
Risk
An overloaded electrical circuit can increase the risk of a fire.
Remedy
Altec will install a new GFCI outlet with a circuit-breaker and new wiring, free of charge. Owner notification letters are expected to be mailed August 29, 2022. Owners may contact Altec's customer service at 205-991-7733. Altec's number for this recall is CSN 3008.
Altec Industries Inc. (Altec) is recalling certain 2016-2018 AT200A vehicles built on Ford E-350 Cutaway chassis. The rear tire size and load rating may be incorrect, possibly resulting in the vehicle being overloaded.
Risk and remedy
Risk
An overload condition may reduce the vehicle's stability or result in tire failure, increasing the risk of a crash.
Remedy
Altec will notify owners, and dealers will inspect the tires and replace any that are not the correct size and load rating, free of charge. The recall began May 22, 2020. Owners may contact Altec customer service at 1-877-462-5832.
Technical service bulletins and other communications the manufacturer sent dealers about this vehicle. Ask a dealer for the full document by its number.
10200430Some customers have reported a crack in the side plate of the mounting frame on some AT200A aerial devices built on Ford F450/F550 chassis from 2011 to 2016 with non-steel utility bodies. Altec requires that each unit be inspected for cracking in the mounting frame side plate no later than the next periodic maintenance interval. Altec requires the kit to be installed within one year of the inspection if the side plate has no cracking or within 90 days of the inspection if the side plate is partially cracked. If the side plate is fully cracked, the unit must be taken out of service until the kit is installed. The inspection and repair are covered under the Altec Warranty Policy and can be performed by Altec, the customer, or the customers warranty provider. All welds must be applied by a welder having the AWS D1.1 3G qualification for steel. An Altec Mobile Service technician can perform this inspection but is not able to perform this repair. Altec will perform the repair for free at an Altec facility.
10200429Some customers have reported a crack in the side plate of the mounting frame on some AT200A aerial devices built on Ford F450/F550 chassis from 2011 to 2016 with steel utility bodies. Altec requires that each unit be inspected for cracking in the mounting frame side plate no later than the next periodic maintenance interval. Altec requires the kit to be installed within one year of the inspection if the side plate has no cracking or within 90 days of the inspection if the side plate is partially cracked. If the side plate is fully cracked, the unit must be taken out of service until the kit is installed. The inspection and repair are covered under the Altec Warranty Policy and can be performed by Altec, the customer, or the customers warranty provider. All welds must be applied by a welder having the AWS D1.1 3G qualification for steel. An Altec Mobile Service technician can perform this inspection but is not able to perform this repair. Altec will perform the repair for free at an Altec facility.
10185150Altec has discovered that the protective fabric hose sock used on the hoses running from the fiberglass upper boom to the platform may extend into the insulating portion of the upper boom. This can cause the dielectric performance of the unit to be reduced if the sock has absorbed water or oil. Altec requires the hose sock length to be inspected on each unit and shortened if necessary to keep it out of the insulating portion of the boom. The inspection and repair must be completed no later than the next regular maintenance interval.