Vehicle description: motor homes equipped with aqua-hot heating systems, model 431-3 zone with engine loop. fiberglass insulating material located under the burner head on the floor of the heater enclosure, can become soaked with fluids (ethylene glycol and/or diesel fuel).
Risk and remedy
Risk
If an electrical short occurs, a fire could result.
Remedy
Dealers will remove the insulation from beneath the diesel heating unit as well as from behind the control thermostat and air-conditioning heating element access covers.
Technical service bulletins and other communications the manufacturer sent dealers about this vehicle. Ask a dealer for the full document by its number.
10128588Blue Bird Troubleshooting Guides: Blue Bird announcement of the addition of troubleshooting guides for assisting in the service of the Blue Bird products. These troubleshooting guides are available on the Vantage website.
Every Blue Bird Wanderlodge model year