12 recalls name the 2008 Spartan Metrostar. Newest first.
Marion Body Works Inc. (Marion Body Works) is recalling certain 2005-2020 Emergency Response Gladiator and Metrostar vehicles equipped with pneumatically-controlled automatic tire chain systems. The air pressure control lines may not be pressure-protected.
Without the control line being pressure-protected, in the event the control line is severed, air may suddenly be lost from the service reservoir system, causing the brakes to apply unexpectedly, increasing the risk of a crash.
Marion Body Works will notify owners, and dealers will inspect the routing of the control lines, rerouting them into the auxiliary air reservoir as necessary, free of charge. The recall began November 22, 2019. Owners may contact Marion Body Works customer service at 1-715-754-5261 or Spartan customer service at 1-800-543-5008.
Spartan Motors USA (Spartan) is recalling certain 2004-2020 Emergency Response Gladiator and Spartan vehicles equipped with a pneumatically-controlled automatic tire chain system. The air pressure control lines may not be pressure-protected. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS)…
Without the control line being pressure-protected, in the event the control line is severed, air may suddenly be lost from the service reservoir system, causing the brakes to apply unexpectedly, increasing the risk of a crash.
Spartan will notify owners, and dealers will inspect the routing of the control lines, rerouting them into the auxiliary air reservoir as necessary, free of charge. The recall began October 4, 2019. Owners may contact Spartan customer service at 1-800-543-5008. Spartan's number for this recall is 19017.
Spartan Motors USA (Spartan) is recalling certain 2001-2019 Spartan MetroStar and Gladiator emergency vehicles. The mounting fasteners for the Emergency Medical Service (EMS) cabinets may not be the correct size, allowing the cabinets to break free from their mountings in the event of a crash.
If the EMS cabinets become loose during a crash, the cabinets may become projectiles, increasing the risk of injury.
Spartan will notify owners, and dealers will replace the incorrect size fasteners with the correct fasteners, free of charge. The recall began November 30, 2018. Owners may contact Spartan customer service at 1-800-543-5008. Spartan's number for this recall is 18030.
Spartan Motors USA (Spartan) is recalling certain 2001-2018 Spartan Gladiator, Diamond, MetroStar, and Advantage emergency response vehicles. The affected vehicles may not be equipped with a pressure protection valve installed between the air reservoir and the lubrication control module. If the air line were to become disconnected between the lubrication…
A loss of air to the air brake system could increase the risk of a crash.
Spartan will notify owners, and dealers will inspect the vehicles and install a pressure protection valve, as necessary, free of charge. The recall began on June 26, 2018. Owners may contact Spartan customer service at 1-800-543-5008. Spartan's number for this recall is 18017.
Spartan Motors USA (Spartan) is recalling certain 2008-2017 Gladiator and MetroStar emergency response vehicles equipped with a supplemental park brake system (SPBS). The directions to activate the SPBS incorrectly state to "Pull" the actuation knob, when it should say "Push."
If the operator follows the incorrect directions and believes that the supplemental front park brake is applied when it is not, the vehicle may unexpectedly roll, increasing the risk of a crash.
Spartan will notify owners and supply a new actuator control knob with the correct directions, free of charge. The recall began on May 22, 2017. Owners may contact Spartan customer service at 1-517-543-6400. Spartan's number for this recall is 17009.
Spartan Motors USA (Spartan) is recalling certain model year 2008-2010 Gladiator, and MetroStar emergency vehicles manufactured December 12, 2008, to August 6, 2010. The affected vehicles have mirror lenses that may fall off due to vibration.
If the mirror lens comes loose and and falls out, the driver's ability to see objects in the mirror would be impaired, increasing the risk of a crash.
Spartan will notify owners, and dealers will install a new mirror assembly, free of charge. The recall began on October 30, 2015. Owners may contact Spartan cutomer service at 1-800-582-3454. Spartan's number for this recall is 15016.
Spartan Motors, Inc. (Spartan) is recalling certain model year 2007-2015 Advantage, Diamond, Gladiator, and MetroStar emergency response vehicles manufactured January 18, 2007 to February 9, 2015. The front wheels of the affected vehicles have valve stems that may rub against the brake caliper.
If the valve stems rub against the brake caliper, a hole may develop causing the tire to deflate suddenly, increasing the risk of a crash.
Spartan will notify owners, and dealers will inspect the front wheel valve stems and replace any that have wear marks, free of charge. The recall began on September 2, 2015. Owners may contact Spartan customer service at 1-517-543-6400. Spartan's number for this recall is 15012.
Spartan Motors, Inc. (Spartan) is recalling certain model year 2006-2013 Advantage, Diamond, Gladiator, and MetroStar emergency vehicles manufactured November 29, 2005, to June 19, 2013. In the affected vehicles, the transmission fluid cooler may fail, allowing the engine coolant to mix with the transmission fluid.
If the engine coolant mixes with the transmission fluid, the transmission may not shift properly, increasing the risk of a crash.
Spartan will notify owners and dealers will install a new transmission fluid cooler, free of charge. Parts are not currently available. Owners were mailed an interim notification on November 25, 2014 and will also be mailed a second letter when parts are available. Parts should be available in mid to late January 2015. The recall began on February 9, 2015. Owners may contact Spartan customer service at 1-517-543-6400. Spartan's number for this recall is 14017.
Spartan chassis (spartan), IS recalling certain model year 2008 diamond, model year 2008-2009 furion along with model year 2011, model year 2010 furion r/t, model year 2007-2012 gladiator, model year 2008-2012 metrostar and model year 2012 spartan force emergency rescue transport vehicles equipped with an electronic stability control (esc) manufactured from…
This might cause the esc to perceive an over steering situation and therefore apply the front axle outer wheel service brake until the vehicle IS perceived to be stable by the esc. These conditions could increase the risk of a crash.
Spartan will notify owners and replace the control module free of charge. the safety recall began on december 19, 2011. owners may contact spartan at 1-800-543-5008 option 5.
Spartan IS recalling certain model year 2008 through 2010 gladiator, metrostar, furion, and diamond fire apparatus and ambulance chassis manufactured from january 29, 2008 through january 25, 2010, equipped with meritor wabco electronic stability control systems (esc). in certain cases, the esc may inadvertently interpret vehicle instability, even though…
Inadvertent brake application to a selected wheel may cause the drive to try and over correct, possibly resulting in a vehicle crash.
Spartan will notify owners and authorized service centers will perform the repairs free of charge. the safety recall began on july 12, 2010. owners may contact spartan at 1-800-543-5008, option 5.
Spartan IS recalling certain model year 2007 through 2009 gladiator, metrostar, advantage, and diamond fire apparatus chassis manufactured from january 1, 2007 through april 15, 2010, equipped with independent front suspensions supplied by ridewell corporation. bell crank support brackets installed on the suspension cradle may crack, or separate, from the…
A complete separation of the bell crank support bracket(s) may cause steering impairment which could result in a vehicle crash.
Spartan will notify owners and repair the vehicles free of charge. the safety recall began on may 26, 2010. owners may contact spartan at spartan chassis at 1-800-543-4277 - option 1.
Spartan IS recalling certain model year 1998 through 2010 advantage, barron, gladiator, metrostar, mountain star, and TR-1 fire apparatus chassis cabs manufactured between february 27, 2003 and november 17, 2009 and belts sold to various vehicle alters. certain seat belt anchorages fail to conform to the requirements of federal motor vehicle safety…
The seat belt may separate from the cab during a vehicle crash and fail to properly restrain the occupant. this may result in personal injury to the seat occupant.
Spartan will notify owners and repair the vehicles free of charge. the safety recall began on june 2, 2010. owners may contact spartan chassis at 1-800-543-4277 - option 1.
Vehicle IS in motion (does not occur from a standing start); after slowing down and then upon depressing throttle in order to accelerate, the truck begins a severe hopping/jerking motion. speed at which hopping/jerking motion occurs IS near 35 miles per hour. incidents have occurred multiple times with at least eight different drivers at various locations sometimes on level ground and sometimes on grades. have contacted manufacturer multiple times and the result was only that drivers required additional training to prevent toe hopping. several of the drivers have driven similar size and weight trucks for over 20 years.